Upstreams Lost

January 12, 2022 at 8:06 AM UTC

Main Gateway

Resolved after 143h 5m of downtime. January 18, 2022 at 7:11 AM UTC

Issue On some PoP’s of Pluto’s we appear to have lost 2 upstreams, these are:

This is because, for AD (AS213045) - the server the connection was on has had to have been restarted, and hence the connection dropped and can’t be re-established. Then The Constant Company is unknown, we are working that one out. This renders prefix 2a0d:2582:170::/44 un-reachable.

Update We have solved The Constant Company, their filters where blocking my prefix for some reason, solved now. Awaiting a bit of support on AD as the BGP session isn’t working.

Final Message The solution for AD was to move the session, as the other server doesn’t work with it. OPTIX sometimes drops out of AS paths, but we have re-aquired FreeTransit.ch.